Upgrades include
• Minimum detection limits down to 0.5 ppb
• Negligible temperature response
• Minimal humidity response
• Integral shielding
• Reduced dead volume
• Reduced and improved response time
• Lower pricing
Intrinsically safe design and 4P platform make installation in
portable or stationary gas monitors a snap.
Â
Features and Benefits
• Intrinsically safe
• Saves time and money in R&D and product design
• 4P cell platform compatible
• Variety of ranges and lamp energies
• Quick start lamp ignition circuit
• Long lamp life
• Input voltage regulation for greater stability
• Easily cleaned and field serviced
• Out of warranty Sensor Exchange Program
Â
10.6eV | Green | Purple | Red | Yellow | Blue |
Part Number | 045-010 | 045-011 | 045-012 | 045-013 | 045-014 |
Range * | 10,000 ppm | 2,000 ppm | 200 ppm | 20 ppm | 2 ppm |
MDQ * | 500 ppb | 100 ppb | 10 ppb | 1.5 ppb | 0.5 ppb |
T90 response Factor | ≤ 2 sec (typical) | ≤ 2 sec (typical) | ≤ 2 sec (typical) | ≤ 4 sec (typical) | ≤ 4 sec (typical) |
Applications
• Industrial Hygiene & Safety Monitoring
• Confined Space Entry
• Soil Contamination and Remediation
• Hazmat Sites & Spills
• Low Concentration Leak Detection
• Indoor Air Quality
• EPA Method 21
Â
Physical Characteristics All sensors calibrated with Isobutylene
Complete sensing unit includes detector cell, UV lamp, lamp driver, amplifier and sample filter
Weight | < 8 gr |
Package Type | 4P cell dimensional profile |
Serviceable Parts | lamp, detector cell, filters (2), cap, spacer |
Lamp Life | Guaranteed 6000 hours - Typical life significantly longer |
Onboard Filters | Removes liquids / particles |
Warranty Period | 1st of 18 months from ship date or 12 months from install date |
Electrical Characteristics
Supply Voltage | 3.2V-5.5V (input voltage regulator included) |
Current | 24mA - 36mA |
Power Consumption | 80 mW - 200 mW - Dependent upon supply voltage |
Output Signal | 0.045V - 2.5V |
Operating Conditions
Temperature Range | -20o C to 60ºC (-4o F to 104ºF) |
Relative Humidity Range | 0 to 90% non-condensing |
Humidity Response | < 1 % @ 90% relative humidity |
Humidity Quenching Effect | < 15% @ 90% relative humidity |
Accuracy | ±3% of reading, with constant temperature and pressure |
Certifications & Approvals*
piD-TECH eVx is a UL certified component. Intrinsically safe - no external components required.
USA | UL 913 (Eighth Edition), For use in Class I, Division 1, Groups A, B, C, D Locations. |
Europe | ATEX directives: EN 60079-0:2012, A11:2013; EN 60079-11:2012, Ex II 1 G Ex ia IIC Ga T4, Tamb = -20C to +60C ATEX Certificates: DEMKO 13 ATEX 1304446U Rev.1; CE 0539 |
Other | IECEx Standards:60079-0 Ed.6; 60079-11, Ed6; Certificate IECEx UL 13.0050U Issue:1; CAN/CSA C22.2 No. 157-92 |
Patents | US Pat 6,646,444, Japan Pat 3,793,757 |
Mechanical Specifications

Â
4-layer Medical Treatment PCB Board, Base Material: FR4 TG135. inner/outer copper thickness 1/1.5 oz. Immersion Gold 3U" surface finished. With green colour solder mask and white silkscreen. Board thickness 1.0 mm. Min.line width/Min.line spacing 0.12/0.15 mm. 20-up connect with the routed&v-cut, 100% E-test pass. there are Vias in pad need to be filled with resin and copper cap. Outline Profile tolerance +/-0.1 mm. line width / distance tolerance +/-15%. hole copper 30 um.The medical treatment PCB boards are usually of high precision, strict control of various tolerances required
Medical Treatment PCB Board,Medical Treatment PCB Panel,Medical Treatment Circuit Board,Circuit Board Etching
Orilind Limited Company , http://www.orilind.com