Mv Vacuum Circuit Breaker

Model NO.: FAR
Poles Number: 3
Type: Circuit Breaker
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification: VDE, ISO9001-2000, Type Tested
Product Name: 12kv 15kv Outdoor Pole Mounted Auto Circuit Reclos
Mechanism Life: 10000 Times
Rated Current: 630A Auto Recloser
Trademark: FARADY
Transport Package: Wooden Case
Specification: IEC56, IEC62271-100, GB1984, DL402(ANSI C37)
Origin: Zhejiang, China
HS Code: 8535900090
Model NO.: FAR
Poles Number: 3
Type: Circuit Breaker
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification: VDE, ISO9001-2000, Type Tested
Product Name: 12kv 15kv Outdoor Pole Mounted Auto Circuit Reclos
Mechanism Life: 10000 Times
Rated Current: 630A Auto Recloser
Trademark: FARADY
Transport Package: Wooden Case
Specification: IEC56, IEC62271-100, GB1984, DL402(ANSI C37)
Origin: Zhejiang, China
HS Code: 8535900090

++++General
Farady Powertech strives to bring our customers the latest technology and competitive pricing and best service for pole mounted Auto circuit recloser
The FAR series Auto circuit recloser can use on overhead distribution lines as well as distribution substation applications for all voltage classes 11kV up to 38kV at 50/60HZ power system. And its rated current can reach 1600A.
The FAR series Auto circuit recloser integrates the functions of control, protection, measurement,communication,fault detection,on-line monitoring of closing or opening.comply to  IEC62271 and ANSI/IEEE C37.60 standard
++++Service environment
a) Air temperature: Maximum temperature: +85ºC; Minimum temperature:-45ºC
b) Humidity: Monthly average humidity 95%; Daily average humidity 90% .
c) Altitude above sea level: Maximum installation altitude: 2500m or more higher.
d) Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.
e) No frequent violent shake
++++Technical data
 

No. Item Unit data
1 Rated voltage kV 15 27 38
2 Rated current A 630 1250 1600
3 Rated frequency HZ 50/60
4 Power frequency 1min Dry kV 50 65 85
Wet 45 55 75
5 Lightning impulse withstand voltage(peak value)alternate, opposite/fracture kV 110 150 170
6 Rated short circuit breaking current kA 20 16/25 12.5
7 Rated short current switching current(peak value) kA 50 40/63 31.5
8 Rated peak value withstand current kA 50 40/63 31.5
9 4S short time withstand current kA 20 16/25 12.5
10 Rated operating circulate   O-T1-CO-T2-CO-T3-CO-T4-CO
11 Breaking current frequency under rated short circuit times 30
12 Mechanism life times 10000
13 Secondary loop 1 min power frequency withstand voltage kV 2

++++Outline & Sizes for FAR
Mv Vacuum Circuit Breaker
Mv Vacuum Circuit Breaker

++++General
Farady Powertech strives to bring our customers the latest technology and competitive pricing and best service for pole mounted Auto circuit recloser
The FAR series Auto circuit recloser can use on overhead distribution lines as well as distribution substation applications for all voltage classes 11kV up to 38kV at 50/60HZ power system. And its rated current can reach 1600A.
The FAR series Auto circuit recloser integrates the functions of control, protection, measurement,communication,fault detection,on-line monitoring of closing or opening.comply to  IEC62271 and ANSI/IEEE C37.60 standard
++++Service environment
a) Air temperature: Maximum temperature: +85ºC; Minimum temperature:-45ºC
b) Humidity: Monthly average humidity 95%; Daily average humidity 90% .
c) Altitude above sea level: Maximum installation altitude: 2500m or more higher.
d) Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.
e) No frequent violent shake
++++Technical data
 

No. Item Unit data
1 Rated voltage kV 15 27 38
2 Rated current A 630 1250 1600
3 Rated frequency HZ 50/60
4 Power frequency 1min Dry kV 50 65 85
Wet 45 55 75
5 Lightning impulse withstand voltage(peak value)alternate, opposite/fracture kV 110 150 170
6 Rated short circuit breaking current kA 20 16/25 12.5
7 Rated short current switching current(peak value) kA 50 40/63 31.5
8 Rated peak value withstand current kA 50 40/63 31.5
9 4S short time withstand current kA 20 16/25 12.5
10 Rated operating circulate   O-T1-CO-T2-CO-T3-CO-T4-CO
11 Breaking current frequency under rated short circuit times 30
12 Mechanism life times 10000
13 Secondary loop 1 min power frequency withstand voltage kV 2

++++Outline & Sizes for FAR
Mv Vacuum Circuit Breaker
Mv Vacuum Circuit Breaker

Bitcoin Mining Machine

Bitcoin mining machines are one way to obtain bitcoins. Bitcoin is an online virtual currency created by open-source peer-to-peer software. Instead of being issued by a specific currency institution, and produced by the massive computation of a specific algorithm, the Bitcoin economy uses a distributed database of nodes throughout the P2P network to identify and record all transactions. The decentralized nature and algorithm of P2P can ensure that it is impossible to artificially manipulate the value of bitcoin by producing a large number of coins.

Any computer can become a mining machine, but the returns will be low, and it may not mine a single bitcoin in a decade. Many companies have developed specialized Bitcoin mining machines with special mining chips that are tens or hundreds of times faster than normal computers.

Currency system by the user (the user through the key control wallet), trade (trade will be broadcast to the whole currency network) and miners (generated by competition calculation agreed on each node of the chain block, block chain is a distributed public authority books, contains the currency network of all the transactions happened)
Bitcoin miners manage the Bitcoin network by solving the problem of proof-of-work mechanisms with a certain amount of work -- confirming transactions and preventing double payments. Because hashing is irreversible, finding the number of random adjustments required to match is difficult, requiring a trial-and-error process that can predict the total number of times. This is where the proof-of-work mechanism comes into play. When a node finds a solution that matches the requirement, it can broadcast its result to the whole network. Other nodes can then receive the newly solved data block and check whether it matches the rule. If the other nodes calculate the hash value and find that the requirement (the operation goal required by Bitcoin) is satisfied, then the data block is valid and the other nodes accept the data block.
Bitcoin Mining Machine:S19 Pro Hyd Asic Miner,S19 Pro Hyd Antminer Bitmain,S19 Hyd Bitmain Antminer,s19j pro antminer bitmain,whatsminer m50s,etc.

Bitcoin Mining Machine,Antminer S19j Pro,bitcoin Miner,btc mining machine,S19 Pro Hyd

Shenzhen YLHM Technology Co., Ltd. , https://www.ylhm-tech.com