In ELISA experiment

process

In the case, a sample value below the blank value is a frequent problem.

When the sample value is lower than the sensitivity of the kit, it is prone to the phenomenon that the sample value is lower than the blank value, especially in the detection of serum and plasma samples.

The reason,

Biggest problem

Mainly in two aspects, one is the error on the one hand, and the matrix effect on the other hand.

Below

Analyze the principles and solutions of different influencing factors one by one.

one,

on

error

error

can

Divided into three categories, systematic errors, random errors and gross errors.

in

Among these three types of errors, the difference between systematic error and sample value and blank value

No

influences. The ELISA sample values ​​below the blank value are mainly derived from random errors and gross errors in error.

1, random error

Uncontrollable causes cause the measured values ​​to produce randomly distributed errors, subject to a statistically normal distribution. Statistically, the measured value has a 99% confidence limit of ±3SD. If the CV value is 20%, the boundary of the random error is ±60%, that is, the sample value is 20% of the CV value. Below 60% of the blank value, there may be a random error, especially if the blank value has only one value.

Random error

Generally

Cannot be eliminated

of

The mean value that can only be obtained by multiple measurements is as close as possible to the true value.

Solutions to reduce random errors

as follows:

Program

1

:

Increasing the number of repetitions of the blank value is generally considered to be repeated 10 times, and the measured mean is close to the true value.

Scenario 2

:

Improving experimental skills can also effectively reduce the impact of random errors. If the CV value is 5% and the sample value approaches zero, the sample value will not be statistically lower than the blank value by 15%.

2, fault error

The error of error is mainly caused by the negligence of the measurer and the undue error. Negligence errors can be avoided. For the problem that the ELISA sample value is lower than the blank value, the cause of the error is mostly due to the repeated loading of the blank hole HRP or the contamination or the washing is not clean, resulting in a high blank value. In contrast, the sample value is lower than the blank value. value.

The solution is to repeat the experiment and standardize the operation.

two,

on

Matrix effect

In the analysis, the matrix refers to components other than the analyte in the sample. The matrix often has significant interference with the analytical process of the analyte and affects the accuracy of the analytical results. These effects and interferences are called matrix effects.

During the development of the ELISA kit, the standard product cannot use human or animal serum or plasma as a dilution of the standard curve, and only the mimics can be used. There are differences in the protein abundance, complexity, pH and other factors between the simulated and tested samples.

When the matrix of the sample reduces the binding of the antigen-antibody compared to its mimetic, a phenomenon in which the sample value is lower than the blank value is produced. Causes the sample value to fail to calculate the value, or the value is negative.

The most common method of removing matrix effects at present is to establish a calibration curve by using a standard sample of known analyte concentration while keeping the matrix in the sample as constant as possible.

When a single sample or a small number of sample values ​​is lower than the blank value, it may be the cause of the error. In this case, repeating should be added to improve the operation skill. When a large number of samples are below the blank value, the influence of the matrix effect should be considered, and a calibration curve should be established to be corrected.

The above is about the Weiwei Biotechnology Department.

The problem that the ELISA sample value is lower than the blank value

Analysis and corresponding solutions for your reference in the course of the experiment.

Shanghai Jiwei Biotechnology Co., Ltd. is a professional high-tech biotechnology company. The company integrates R&D and sales. Its products range from ELISA kits, standards, cell lines, antibodies and biological reagents. , medium, etc., as well as agents of all kinds of imported reagents, company store address: http:// welcome new and old customers to come to consult and buy!